CLEARANCES
CLEARANCES TO COMBUSTIBLES (both sides)
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/4" from the facing. If it does, it is
considered a mantel and must meet the mantel requirements listed in this manual.
Figure 6 - Clearances
Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or
non-
combustible material panel extending full width and depth of
the appliance.
WARNING
Clearance to
Combustibles
Sides 0
Floor 0
Back 0.5"
Standoff
0"
Front 36"
The fireplace face must be
completely covered with
any non-combustible ma-
terial. Allow clearance for